We use cookies to improve your experience. By your continued use of this site you accept such use. To change your settings please see our Privacy Policy.
關閉

FIB線路修補

材料分析 (MA)

軟體

MA-tek FTP

永續報告書

智財報告書

IC封裝/測試應用實例

Analysis Cases

 
 

Appearance, Dimension Measurement

Optical profiler, OM, SEM

Lead Frame Condition

X-ray, SEM

Defect Isolation

EMMI, OBIRCH

Failure Analysis

X-ray, SAT, Optical profiler, SEM, TEM

Composition Analysis

SEM/EDS, TEM/EDS, FE-AES, XPS, SIMS

ESD Testing

HBM, MM, CDM, Latch-up

 

 

(a) OP;(b) SEM;(c) Metal fingers formation on FPC ;(d) Photo mask inspection

 

 

 

Optical Microscope

 

 

 

 

 

Non Contact 3D Surface Profiler

Applications 

  • Flatness, surface roughness, step height, deformation and waviness
  • 2-D and 3-D profile

 

Advantages 

  • Accurate, fast and no sample preparation is needed
  • An extremely wide range of surface heights is capable to be profiled. (~180μm)
  • The benefits of optical surface profilometry include
    - Excellent height resolution
    - High measurement speed
    - Ability to perform non-contact measurements of delicate surfaces

 

Surface defects characterization

(a) OP;(b) SEM;(c) LED ;(d) Au Bump

  

100 μm Bump Profiler

20 μm Bump Profile

 

 

 

X-ray Photography

Applications

This system was designed specifically for the PCB Assembly Market

  • BGA Inspectin
  • Solder Interconnects of Active & Passive Components
  • Voiding Calculation
  • Hybrid Components

 

Additionally, useful for inspection of electromechanical components, which are encapsulated

  • Sensors
  • Relays
  • Fuses
  • Coils
  • Wirebonds
  • Die-Attach

 

 

Strength

  • Anti-Collision Design
  • AIM Technology with Intuitive Sample Positioning
  • High Magnification, Third Dimension Inspection
  • Dynamic Real-Time Image Processing
  • Open Microfocus X-ray Tube
  • True X-ray Intensity (TXI) Control
  • Ergonomic Workstation
  • Large Board Capability up to 610 mm x 610 mm (24” x 24”)

 


 

 

X-ray Photography Examples

 

 

 

Scanning Acoustic Microscope

This system evaluation is designed specially for semiconductor electronics with molding compound, which will be ideal for examination of minor defects such as,
  • Package crack
  • Delamination
  • Die crack
  • Void in resin
  • Poor die attachment
  • poor wire bonding

 

MA-tek system is featured by 3D imaging, real-time 3D imaging, 0.5 um high resolution, 1000 mm/sec high speed, A-scan, B-scan, C-scan, S-image, and  T-scan. 

 


 

 

Product Failure Analysis

 

(a)I-V Curve;(b)SAT;(c)X-ray;(d)SEM;(e)SEM;(f)SEM

 

 

 

SEM Imaging

 

 

 

 

 

 

 

 

SEM/EDX Mapping Analysis

 



 

Failed Bump after Reliability Testing

(a)OM Image of Post FIB Cutting;(b)FIB cross-sectioning ;(c)TEM Image

 

 

 

High Resistance Bumping Issue

 

 

 

SIMS Applications

 


(a)CAMECA ims-6f ;High Transmission and High Mass Resolution

(b)ATOMIKA sims 4500;High Depth Resolution, Ultra-Shallow Junction

 

  • Ultra-shallow junction analysis
  • Very thin layer (tens angstrom) analysis
  • Doping profile/Depth profile
  • Back side Cu Diffusion
  • Contamination verification
  • Excellent detection limit (ppm to ppb)
  • Can detect all elements and isotopes, including H
  • Excellent depth resolution, 1nm is possible
  • Quantification by standard reference
  • Insulator can be measured

 

(a)Ultra Shallow Junction

(b)High Depth Resolution

 

 

 

Total Solution of ESD Service

Wide Span of Service Scope

  • Various testing modes [HBM, MM, socket CDM, non-socket CDM, latch-up]
  • Room temperature and high temperature testing facility (-20℃ - 225℃)
  • Dynamic Latch-up testing capability - vector input board with high frequency
  • Universal BGA socket for ESD/Latch-up testing
  • COB testing and packaged IC (BGA, QFN, QFP, DIP, TSOP...etc.) testing
  • Wire bonding and packaging services
  • [Au/Al wiring, die mount, epoxy encapsulation]
  • System level testing of module, mother board, and electronic system by ESD gun

 

Customized Service

  • Establishment of ESD/Latch-up design rules
  • Design of I/O cell library, specific pad circuitry
  • Consultancy of ESD protection scheme

 

Cycle Time Commitment

  • Report delivery in 24 hrs, total testing time ≦ 5 hrs
  • Report delivery in 48 hrs, total testing time ≦ 15 hrs